The Protective Effects of CO2 on Fragile Ions in Differential Mobility Spectrometry
Andrew L Finlay1, Wojciech Gabryelski1, W Scott Hopkins2,3
1Department of Chemistry, University of Guelph, Guelph, Ontario N1G 2W1, Canada.
None:
We explore the protective effects of adding CO2 to the N2 carrier gas when we conduct differential mobility spectrometry (DMS) analysis of fragile ions. A selection of fragile analytes of varying chemistries were chosen from our lab inventory and include protonated glycine, methylbenzyl ammonium, methoxybenzylpyridinium, the protonated 2-pentanone dimer, deprotonated GenX (a perfluoroalkyl substance; PFAS), and deprotonated trifluoroacetic acid. By raising the separation voltage or the carrier gas temperature, conditions were set to induce fragmentation of the analyte ions within the DMS collision cell. Subsequently introducing CO2 into the N2 carrier gas at concentrations ranging from 10 - 70% mitigated ion fragmentation and resulted in signal intensity gains of multiple orders of magnitude. Interestingly, stabilization of the fragile ions sometimes occurred without introducing significant ionogram peak shifts (i.e., shifts of less than 1 V), indicating that these ions exhibit relatively weak interactions with the CO2 modifier. Electronic structure calculations yield Gibbs binding energies of ca. - 1 kJ mol-1 under the DMS conditions employed, further supporting the hypothesis that dynamic ion-CO2 clustering is not the root cause of the observed protective effect. The addition of CO2 was also found to stabilize noncovalently bound dimers, presumably generated at the ionization source. These results indicate that, in these examples, CO2 cools the ions in the energetic DMS environment via momentum transfer and energy partitioning, and that introducing CO2 into DMS gas mixtures could enable the stabilization, separation, and analysis of fragile analytes.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Chemical Ionization (CI) Mass Spectrometry
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)