Related Experiment Video
Updated: Sep 10, 2025

Imaging Approaches to Assessments of Toxicological Oxidative Stress Using Genetically-encoded Fluorogenic Sensors
Published on: February 7, 2018
A Light-Up Fluorescent Probe for Detection of Reactive Oxygen Species and a Nerve Gas Simulant: Applications in
Dipanjan Banik1, Anwesha Maiti1, Satyajit Halder2,3
1Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal, 711103, India.
Abstract:
A turn-on fluorescent probe, TPIHB, featuring a hydrazinobenzothiazole-appended phenanthroimidazole core, was developed for dual-channel sensing of reactive oxygen species, hypochlorite, and nerve agent simulant diethyl chlorophosphate (DCP), through two distinct mechanistic pathways in biological settings and vapor-phase applications. The probe lighted up with a strong blue signal at 437 nm due to the formation of triazole TPITT through the hypochlorite-induced intramolecular oxidative cyclization. In contrast, DCP-triggered protonation of the secondary nitrogen led to the formation of ICT-enabled TPIHB-DH, resulting in a bright cyan emission at 458 nm in an aqueous THF medium. With excellent selectivity over other ROS and phosphates, the probe displayed a rapid response time of 30 s for hypochlorite and 14 s for DCP. Additionally, it displayed high sensitivity, with detection limits of 13.73 nM for hypochlorite and 16.96 nM for DCP. Moreover, TPIHB was employed to monitor hypochlorite in environmental water samples, in solid-state TLC strip studies, in commercial disinfectants, exogenous bioimaging in human breast cancer cells (MDA-MB 231), and endogenous bioimaging in RAW 264.7 macrophage cells with very low cytotoxicity and good cell viability. On the other hand, aiming at real-world applicability, a probe-embedded filter paper strip was fabricated, designed for real-time sensing of DCP vapor through smartphone-supported analysis, and also with cotton biopolymer as the supporting matrix.
More Related Videos
14:25Quantification of Reactive Oxygen Species Using 2′,7′-Dichlorofluorescein Diacetate Probe and Flow-Cytometry in Müller Glial Cells
Published on: May 13, 2022
09:31Analyzing Oxidative Stress in Murine Intestinal Organoids using Reactive Oxygen Species-Sensitive Fluorogenic Probe
Published on: September 17, 2021
Related Concept Videos
Photoluminescence: Applications
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...