A 28 mK Resolution, -0.45 °C/+0.51 °C Inaccuracy Temperature Sensor Using Dual-Comparator Architecture and Logic-Controlled Counting Method
Related Experiment Video
Updated: Sep 8, 2025

Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
Published on: January 5, 2014
Yubin Xu1,2, Tongyu Luo1,2, Lin Peng1,2
1School of Electronics and Communication Engineering, Guangzhou University, Guangzhou 510006, China.
Abstract:
This paper presents an all-CMOS temperature sensor with low power consumption, wide temperature range, and high precision in a 180 nm CMOS process. Based on the I-V characteristics of MOSFETs in the subthreshold region and the negative exponential biasing current generated by the self-bootstrapped bias circuit, the proposed temperature-sensing front-end produces CTAT and PTAT voltages with high linearity and high sensitivity. The voltage-to-time converter (VTC) adopts a dual-comparator architecture to expand the time interval for improving resolution. The control logic unit is designed to count only within the time interval, eliminating interference during low-level periods and enhancing the accuracy of temperature measurement. The implemented sensor achieves an inaccuracy of -0.45 °C/+0.51 °C (3σ) from -40 °C to 130 °C after a two-point calibration with a resolution of 28 mK and consumes 503 nW at 27 °C when operating at 1 V, with an FoM of 7.9 pJ·K2.
Related Concept Videos
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Operational Amplifiers
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Voltage Dividers