High spatiotemporal-resolution abdominal 4D-MRI through respiratory-synchronized frame collaborative reconstruction
Yinghui Wang1, Lu Wang1, Yidan Feng2
1Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China.
Medical Physics
|September 10, 2025
Summary
This study introduces MCR-Net, a novel method to improve four-dimensional magnetic resonance imaging (4D-MRI) for radiotherapy. MCR-Net enhances image quality by using information across multiple frames, overcoming limitations in spatial and temporal resolution.
Area of Science:
- Medical Imaging
- Radiotherapy Guidance
- Image Reconstruction
Background:
- Four-dimensional magnetic resonance imaging (4D-MRI) is crucial for abdominal radiotherapy.
- Current 4D-MRI suffers from low spatial/temporal resolution and motion artifacts due to undersampling.
- Existing methods fail to fully utilize redundant frame information for detail restoration.
Purpose of the Study:
- Develop a novel technique to improve spatiotemporal resolution in abdominal 4D-MRI.
- Mitigate spatial undersampling by effectively leveraging multi-frame information.
- Enhance image quality for better clinical implementation in radiotherapy.
Main Methods:
- Introduced a multi-frame collaborative reconstruction network (MCR-Net) for 4D-MRI.
- Integrated an Inter-frame mutual-attention mechanism (IMM) to exploit inter-frame correlations and suppress noise.
- Utilized a structure-aware consolidation module (SaCM) for enhanced structural detail recovery and artifact reduction.
Main Results:
- MCR-Net significantly outperformed nine state-of-the-art methods in visual quality and quantitative accuracy (MAE, SSIM, PSNR).
- Achieved superior performance metrics: 3.77% (MAE), 1.03% (SSIM), and 6.74% (PSNR) improvement over next-best methods.
- Demonstrated enhanced registration accuracy (10.66% MAE, 3.60% SSIM, 1.94% NCC) and maintained quality under increased undersampling.
Conclusions:
- MCR-Net effectively suppresses artifacts and recovers anatomical structures from undersampled 4D-MRI data.
- The method has the potential to significantly improve 4D-MRI's spatiotemporal resolution.
- MCR-Net can advance clinical applications in abdominal radiotherapy guidance.