Related Experiment Video
Updated: Jul 21, 2026

Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
Evaluation of color stability and material surface stability of different types of clear aligners under curcumin
Ketai He1, Mingjie Xu1, Wen Liao2
1State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, China.
Abstract:
Aesthetics play a crucial role in patients' choice of orthodontic clear aligners, as poor color stability can compromise their appearance during wear. This study aimed to evaluate the color and surface stability of different types of orthodontic clear aligners exposed to various concentrations of curcumin solutions in vitro. Four types of clear aligners (Invisalign, Angelalign, Spark, and Dreve), along with non-thermoformed Dreve film, were cut into 5 mm × 5 mm squares and immersed in curcumin solutions of different concentrations and a control solution. The concentrations were determined based on the curcumin content in curry. Anhydrous ethanol was used as the solvent, which may influence surface properties and color stability and partially simulating damage caused by alcohol consumption or bacterial metabolites. After immersion for 12 h and 7 days, the squares were ultrasonically cleaned, and color changes were measured using a colorimeter, then converted to National Bureau of Standards (NBS) units. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to observe surface characteristics before and after staining. After 12 h of immersion in 10 µg/ml solutions, all samples except the Dreve film exhibited at least an "Appreciable: marked change," with Angelalign showing a more pronounced color alteration. After 7 days of immersion, most materials displayed color changes ranging from "Much: extremely marked change" to "Very much: change to other colors." Across all concentrations and time points, Invisalign aligners exhibited significantly higher ΔE* values than Dreve (P < 0.05). Although SEM and AFM results were not entirely consistent, both indicated that PU-based aligners were more susceptible to surface morphology changes than PET-G-based aligners. Enhancing the aesthetic color stability of orthodontic materials could contribute to improved clinical outcomes.
More Related Videos
03:37Evaluating the Effects of Different Polishing Methods on Color Stability of Dental Restorations in Pediatric Dentistry
Published on: June 6, 2025
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
Related Concept Videos
Indicators
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Differential Staining Technique