Related Experiment Video
Updated: Jan 16, 2026

Single-Particle Cryo-EM Data Collection with Stage Tilt using Leginon
Published on: July 1, 2022
Ultra-high resolution tilt calibration and real-time compensation for cold atom gravimeters
Zhiye Song1,2, Yaning Wang3, Guangming Wang1,2
1College of Intelligence Science and Technology, National University of Defense Technology, Changsha 410073, China.
None:
The angular misalignment between two Raman beams is a critical source of error in gravity measurements using cold atom gravimeters. This paper presents the design and experimental validation of an integrated optical fiber module based on the principle of optical reversibility. The proposed module enables calibration of Raman beam polarization orthogonality and overlap angles while simultaneously providing real-time compensation for gravity measurement errors induced by Raman beam misalignment through continuous monitoring of the calibration signal. Experimental results demonstrate that the module achieves a Raman mirror tilt angle calibration accuracy of 1.6 arc sec, corresponding to a gravity acceleration calibration accuracy of 0.06 μGal. The implementation of this module enhances calibration efficiency, mitigates alignment-related disturbances, and improves the overall stability of atomic gravimeter measurements. Its versatility makes it suitable for deployment in both high-accuracy stationary laboratory experiments and dynamic field applications, advancing the practical utility of cold atom gravimeters in geophysical and metrological research.
Related Concept Videos
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Gyroscope: Precession

