Related Experiment Video
Updated: Jan 16, 2026

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Towards a cardiovascular magnetic resonance foundation model for multi-task cardiac image analysis
Athira J Jacob1, Indraneel Borgohain2, Teodora Chitiboi3
1Digital Technology and Innovation, Siemens Healthineers, Princeton, New Jersey, USA; AI in Healthcare and Medicine, Technical University of Munich, Munich, Germany.
Background:
Cardiovascular magnetic resonance (CMR) is a complex imaging modality requiring a broad variety of image processing tasks for comprehensive assessment of the study. Recently, foundation models (FM) have shown promise for automated image analyses in natural images (NI). In this study, a CMR-specific vision FM was developed and then finetuned in a supervised manner for nine different imaging tasks typical to a CMR workflow, including classification, segmentation, landmark localization, and pathology detection.
Methods:
A ViT-S/8 model was trained in a self-supervised manner using DINO on 36 million CMR images from 27,524 subjects from three sources (UK Biobank and two clinical centers). The model was then finetuned for nine tasks: classification (sequence, cine view), segmentation (cine SAX, cine LAX, LGE SAX, Mapping SAX), landmark localization, pathology detection (LGE, cardiac disease), on data from various sources (both public and three clinical datasets). The results were compared against metrics from state-of-the-art methods on the same tasks. A comparable baseline model was also trained on the same datasets for direct comparison. Additionally, the effect of pretraining strategy, as well as generalization and few-shot performance (training on few labeled samples) was explored for the pretrained model, compared to the baseline.
Results:
The proposed model obtained similar performance or moderate improvements to results reported in the literature in most tasks (except disease detection), without any task-specific optimization of methodology. The proposed model outperformed the baseline in most cases, with an average increase of 6.8% points (pp) for cine view classification, and 0.1 to 1.8 pp for segmentation tasks. The proposed method also obtained generally lower standard deviations in the metrics. Improvements of 3.7 and 6.6 pp for hyperenhancement detection from LGE and 14 pp for disease detection were observed. Ablation studies highlighted the importance of pretraining strategy, architecture, and the impact of domain shifts from pretraining to finetuning. Moreover, CMR-pretrained model achieved better generalization and few-shot performance compared to the baseline.
Conclusions:
Vision FM specialized for medical imaging can improve accuracy and robustness over NI-FM. Self-supervised pretraining offers a resource-efficient, unified framework for CMR assessment, with the potential to accelerate the development of deep learning-based solutions for image analysis tasks, even with few annotated data available.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

