Related Experiment Video
Updated: Jan 6, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Robust fractional-order adaptive cascaded strategy for mitigating load frequency deviations in renewable thermal
Youssef M Abdel Halim1, Othman A M Omar2, Mahmoud A Attia3
1Electrical Power and Machines Department, Faculty of Engineering, Ain Shams University, Cairo, 11517, Egypt.
None:
In modern power systems, the increasing share of renewable energy sources (RES) is primarily due to their environmental benefits and sustainability. However, because RES like wind and solar are inherently variable and intermittent besides interfacing with the grid mainly through power electronic devices, they act mainly as power injectors rather than conventional synchronous generators. This results in a reduction of system inertia, intensifying frequency stability challenges. To address this problem, this paper proposes a robust cascaded control strategy for mitigating load frequency deviations in a two-area hybrid renewable-thermal power system. The proposed controller integrates a fractional-order adaptive PID (FOAPID) with a harmony search-optimized PIDA (HS-PIDA), combining the adaptability of Caputo fractional derivatives and model reference adaptive control with the accelerated derivative action of PIDA to enhance dynamic performance. The system model incorporates solar PV, wind, and conventional thermal units, capturing nonlinearities and renewable variability. Six case studies are performed to assess robustness against step and dynamic load changes, renewable intermittency, and parameter uncertainties. Results reveal that the proposed controller reduces settling time for frequency deviations to as low as 3.1 s compared to 14-18 s for TLBO PIDA, SCA PIDA, and Fuzzy PID. Undershoot values are decreased by more than 80% across all cases, while steady-state errors are eliminated where competing controllers failed to converge. Error indices confirm superiority, with SSE reductions of up to 99% and RMSE reductions of up to 97% compared to alternative controllers. Against Marine Predator Algorithm (MPA)-Cascaded PIDA, the proposed scheme further improves overshoot and undershoot by up to 89.85% and achieves faster convergence, proving its effectiveness under diverse operating conditions.
More Related Videos
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Related Concept Videos
Load-frequency control
Fast Decoupled and DC Powerflow
Turbine-Governor Control
Control of Power Flow
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
The Power Flow Problem and Solution