Related Experiment Video
Updated: Jan 15, 2026

Functional Near-Infrared Spectroscopy Hyperscanning Study in Psychological Counseling
Published on: January 17, 2025
[Reliability and validity study of the short version of the Chinese version of the Burnout Assessment Tool (BAT-12)]
Abstract:
Objective: To verify the reliability and validity of the short version of the Chinese version of the new Burnout Assessment Tool (12 items version of Burnout Assessment Tool, BAT-12) . Methods: From October to December 2023, the cluster sampling method was adopted, and the Chinese version of the Maslach Burnout Inventory-General Survey (MBI-GS) and the BAT-12 scale were used simultaneously. A questionnaire survey was conducted among enterprise employees (4329 people) in Shanghai and Guangdong Province. Exploratory factor analysis and confirmatory factor analysis and other methods were employed to analyze its reliability (internal consistency reliability and combination reliability) and validity (structural validity, convergent validity, discriminative validity and criterion validity) . Results: A total of 4329 questionnaires were retrieved, among which 4086 were valid, with an effective recovery rate of 94.39%. The Cronbach's α coefficient of the Chinese version of the BAT-12 total scale was 0.956, and the combination reliability coefficients of each dimension ranged from 0.914 to 0.952. The scale contained 12 items, and 4 common factors were extracted from exploratory factor analysis, including exhaustion, mental distance, cognitive impairment, and emotional impairment. The cumulative variance contribution rate reached 86.63%. Confirmatory factor analysis showed that both the four-factor correlation model and the second-order model were ideally fitted overall, with the four-factor correlation model having the best data fit (comparative fit index 0.972, Tuker-Lewis fit index 0.962, root mean square error of approximation 0.064, and standardized root mean square residual 0.033). The average variance extracted (AVE) of each dimension of the scale ranged from 0.780 to 0.868, and the square roots of AVE (0.883 to 0.932) were all greater than their Pearson correlation coefficients (0.630 to 0.850). The Pearson correlation coefficient between BAT-12 and MBI-GS was 0.787 (P<0.001) . Conclusion: The Chinese version of the BAT-12 scale demonstrates strong internal consistency and combination reliability, with excellent reliability. Its four-dimensional structure validity has been validated, with good convergent validity, discriminative validity, and ideal criterion validity, demonstrating excellent validity. The Chinese version of the BAT-12 scale can be used to measure the level of occupational burnout among Chinese employees.
Related Concept Videos
Reliability and Validity
Self-Report Tests of Personality

