Related Experiment Video
Updated: Jan 15, 2026

Mechanical Separation and Protein Solubilization of the Outer and Inner Perivitelline Sublayers from Hen's Eggs
Published on: January 27, 2021
Dielectric Properties and Heating Rates of Egg Components Associated with Radio Frequency and Microwave
Feixue Yang1,2, Jianhang Hu1,2, Huijia Li1,2
1College of Food and Bioengineering, Zhengzhou University of Light Industry, Zhengzhou 450001, China.
None:
Salmonella spp. outbreaks associated with eggs have attracted widespread concerns about food safety. To provide necessary information for further pasteurization processes and computer simulations induced by radio frequency (RF) and microwave (MW) energy, the dielectric properties, penetration depth, and heating rates of egg white, yolk, and eggshell were measured, calculated, or fitted by regression models. The results demonstrated that both the dielectric constant and dielectric loss factor of egg white and yolk decreased dramatically with raised frequency within the RF range from 10 to 300 MHz, and then reduced slightly within the MW range from 300 to 3000 MHz. Dielectric constant, and loss factor of egg white, yolk, and eggshell increased with raised temperature. The penetration depth of egg white, yolk, and eggshell decreased with increasing of frequency. RF waves had a deeper penetration depth than that of MW waves at the same temperature. The fourth-order polynomial models provided a good fit to the experimental data with large coefficients of determination (R2 > 0.902). The heating rate of the egg samples increased with increasing RF voltage and microwave power, and the heating rate of yolk was higher than that of egg white or eggshell at the same conditions. This study offers essential data and effective guidance in developing and optimizing RF and MW pasteurization techniques for ensuring the microbial safety of eggs, using both experiments and mathematical simulations.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Standing Waves in a Cavity
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...

