Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device01:30

Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device

378
Surveyors use Global Positioning System (GPS) technology to measure the precise location and elevation of points on Earth. In a recent survey, GPS receivers were used to determine the coordinates and elevations of two park monuments. The process involved careful mission planning, data collection, and correction to ensure accuracy. The survey began with mission planning to identify optimal satellite visibility and minimize Position Dilution of Precision (PDOP). A geodetic control point...
378
Glassware Calibration01:11

Glassware Calibration

1.3K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.3K
Instrument Calibration01:12

Instrument Calibration

678
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
678
Design Example: Marking Boundaries of a Site Using a Compass01:12

Design Example: Marking Boundaries of a Site Using a Compass

281
Marking site boundaries using a compass is a precise surveying technique that ensures the accuracy of boundary delineation. The process begins by using provided site details, including the bearings and lengths of each boundary line. The initial step involves calculating latitudes and departures for all sides of the site. This computation verifies that the traverse is free of errors, ensuring a closed and accurate boundary.The process starts at a known point, such as Point A, which is often...
281
Plotting and Calibrating the Root Locus01:19

Plotting and Calibrating the Root Locus

421
Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
421
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

4.1K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
4.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

HARMONIZATION MITIGATES DIFFUSION MRI SCANNER EFFECTS IN INFANCY: INSIGHTS FROM THE HEALTHY BRAIN AND CHILD DEVELOPMENT (HBCD) STUDY.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same author

Concentric Tube Robot-Assisted Intracerebral Hemorrhage Evacuation: Validation in an Ovine Model.

IEEE transactions on medical robotics and bionics·2026
Same author

HARMONIZATION MITIGATES DIFFUSION MRI SCANNER EFFECTS IN INFANCY: INSIGHTS FROM THE HEALTHY BRAIN AND CHILD DEVELOPMENT (HBCD) STUDY.

ArXiv·2026
Same author

Modeling and Control For Minimally Invasive Intracerebral Hemorrhage Evacuation.

IEEE transactions on medical robotics and bionics·2026
Same author

Alternating-contrast single-shot spiral MR-ARFI with model-based displacement map reconstruction.

Magnetic resonance in medicine·2025
Same author

Development of a Low-Profile, Piezoelectric Robot for MR-Guided Abdominal Needle Interventions.

Annals of biomedical engineering·2025
Same journal

A Compact Photoacoustic Sensing Probe using Surface-Micromachined Optical Ultrasound Transducer (SMOUT).

IEEE sensors journal·2026
Same journal

Shape Sensing of Continuum Manipulators with Fiber Bragg Grating Sensor Arrays: Accounting for Actuator Velocity Effects.

IEEE sensors journal·2026
Same journal

Exploring Variable Achilles Tendon Loading Via Active Acoustics.

IEEE sensors journal·2026
Same journal

Fiber-Tip Surface-Micromachined Optical Ultrasound Transducer (SMOUT) Probe for Acoustic Detection Induced by Ultrahigh Dose Rate (UHDR) Electron Beam.

IEEE sensors journal·2026
Same journal

Development of a Disposable Chemiresistive Biochip for Tear-Based Retinopathy of Prematurity Diagnosis: Early Screening and Risk Prediction.

IEEE sensors journal·2026
Same journal

Power Optimization of TENGs via Load Capacitance Sizing.

IEEE sensors journal·2026
See all related articles

Related Experiment Video

Updated: Jan 14, 2026

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping
09:41

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping

Published on: April 21, 2023

2.1K

Marker-to-Object Calibration Using Landmark Touch.

Letian Ai1, Saikat Sengupta2, Yue Chen3

  • 1Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA 30332 USA.

IEEE Sensors Journal
|October 23, 2025
PubMed
Summary
This summary is machine-generated.

This study presents a new calibration method for precise medical instrument tracking in image-guided interventions. The technique achieves sub-millimeter accuracy, enhancing the reliability of fiducial marker placement for improved clinical outcomes.

Keywords:
Calibrationmarker placementobject tracking

More Related Videos

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
10:23

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans

Published on: September 8, 2023

3.6K
Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
08:24

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

Published on: August 30, 2016

10.6K

Related Experiment Videos

Last Updated: Jan 14, 2026

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping
09:41

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping

Published on: April 21, 2023

2.1K
Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
10:23

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans

Published on: September 8, 2023

3.6K
Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
08:24

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

Published on: August 30, 2016

10.6K

Area of Science:

  • Medical Imaging
  • Robotics
  • Biomedical Engineering

Background:

  • Fiducial markers are crucial for medical instrument tracking in image-guided interventions.
  • Precise marker placement and accurate marker-to-object transformation are challenging, especially for non-standard geometries.
  • Existing methods struggle with accuracy and robustness in complex scenarios.

Purpose of the Study:

  • To introduce a novel calibration method for accurate marker-to-object transformation in image-guided interventions.
  • To improve the robustness and translational accuracy of fiducial marker calibration.
  • To validate the method's effectiveness across different tracking modalities and clinical applications.

Main Methods:

  • A novel calibration method involving sequential touching of object landmarks with a fixed tip.
  • Implementation of an inverse sample consensus filter to mitigate measurement outliers.
  • Validation through simulations and experiments using electromagnetic tracking and magnetic resonance imaging systems.

Main Results:

  • Demonstrated superior translational and rotational accuracy compared to conventional methods.
  • Achieved translational errors of 0.61 ± 0.11 mm (electromagnetic tracking) and 0.60 mm (MRI).
  • Showcased sub-millimeter calibration accuracy in diverse scenarios, including a robotic surgery use case.

Conclusions:

  • The proposed calibration method offers high accuracy and robustness for fiducial marker placement.
  • It is effective across different tracking modalities and suitable for integration into image-guided workflows.
  • The method holds significant potential for advancing research and clinical applications in image-guided interventions.