Analysis of Stability and Functionality of Coil and Piezoelectric Braille Modules Under Varying Temperature
Krzysztof Zbroja1,2, Anna Drabczyk1, Oliwier Sobesto1
1CBRTP SA Research and Development Center of Technology for Industry, Zygmunta Modzelewskiego 77 St., 02-679 Warszawa, Poland.
Abstract:
In this study, the performance and reliability of two different types of Braille modules, i.e., coil and piezoelectric, under varying temperature conditions were compared. The coil module works on the principle of electromagnetic forces generated by coils, while the piezoelectric module is based on the deformation of piezoelectric materials under electric voltage to move needles. The main purpose of this research was to discuss the stability and functionality of both modules within the temperature range from -30 °C to +50 °C. One thousand cycles of operation were conducted for each temperature step in 5 °C increments, focusing on the correctness of needle movement and system reliability. The results demonstrated that the piezoelectric module exhibited stable operation over the entire temperature range, while the coil module showed instabilities, such as self-jamming and overheating, above 20 °C. These problems were probably due to thermal expansion and reduced lubrication efficiency. These results underscore the piezoelectric module's improved adaptation to high-temperature operation, making it a promising solution for applications requiring reliable operation under varying conditions.
Related Concept Videos
Thermal Stress
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Dependent Deformation
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...