Reliability and criterion validity of the concept 2 SkiErg™ to assess 1,000-m on-snow, time trial performance-a case
Brendan J O'Brien1, Ryan Worn1, Brad Clark1,2
1Federation University Australia, Institute of Health and Wellbeing, Mt Helen, VIC, Australia.
Objectives:
This study investigated the reliability and criterion validity of the Concept 2 SkiErg™ to assess 1,000-m on-snow, time trial performance using the classical double poling technique.
Methods:
Ten athletes (5 males and females) from a National cross-country ski team participated in the study and completed a 1,000-m time trial on snow, as well as two 1,000-m time trials on the Concept 2 SkiErg™ in a temperature-controlled room during a 4-day training camp.
Results:
There was a significant decrease in time from test 1 to test 2 of 4.87 s [238.3 ± 26.1 vs. 233.4 ± 23.9 s; 95% limits of agreement (LoA): -5.5, 15.3]. The Concept 2 SkiErg™ time-trial had a coefficient of variation (CV) of 1.6% and the standard error of measurement was 3.8 s. When compared to the on-snow time-trial, the Concept 2 SkiErg™ time-trial demonstrated a mean bias of 20.7 s (95% LoA; 11.6, 29.8) and the concordance correlation coefficient was 0.72.
Conclusion:
The Concept 2 SkiErg™ demonstrated excellent single-trial reliability. However, there was significant proportional bias in the Concept 2 SkiErg™ relative to the on-snow test and agreement between the two was relatively poor. Research using a larger sample and different trial durations is required to further validate the Concept 2 SkiErg™ for cross-country skiing performance testing.
More Related Videos
07:32Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity