Related Experiment Video
Updated: Jan 11, 2026

A Study of the Complexation of MercuryII with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
Quaternized tetraethylenepentamine-capped AgNPs for selective and rapid colorimetric detection of mercury(II) in
Mansour D Alharthi1, Khalid E Alzahrani2, Abdullah M Alswieleh3
1Department of Chemistry, College of Science, King Saud University, Riyadh, Kingdom of Saudi Arabia.
Abstract:
This work utilized silver nanoparticles (AgNPs) capped with both tetraethylenepentamine (TEPA) and quaternized tetraethylenepentamine (Q-TEPA) as stabilizer and selective recognition element for Hg2+ over competing metal ions (Fe2+, Fe3+, Zn2+, Cu2+, Pb2+, Cr3+, Ni2+, Cd2+, Mn2+, As5+, Co2+, Al3+, La3+). The performance of Q-TEPA-AgNPs was compared to TEPA-AgNPs, demonstrating significantly higher selectivity for Hg2+ detection. The effect of Q-TEPA concentration (1 mM, 2 mM, and 4 mM) during the preparation of Q-TEPA-AgNPs on Hg2+ selectivity, limit of detection (LOD), and limit of quantification (LOQ) was investigated. LOD and LOQ values of Q-TEPA(1 mM)-AgNPs and Q-TEPA(2 mM)-AgNPs were ~ 10 µM and ~ 31 µM, respectively. However, the linear detection range was wider for Q-TEPA(1 mM)-AgNPs (spanning 20-150 µM) compared to Q-TEPA(2 mM)-AgNPs (20-100 µM). LOD and LOQ of Q-TEPA(4 mM)-AgNPs increased to ~ 20 µM and ~ 60 µM, respectively, with linear range between 20 and 100 µM. Higher concentration of Q-TEPA enhanced Hg2+ selectivity but adversely increased LOD and LOQ, and narrowed the linear detection range. The response is rapid: after Hg2+ addition the plasmon band disappears within ≤ 12 s, enabling near-real-time visual readout. The nanosensor enabled highly selective Hg2+ sensing and functions effectively under real-world conditions, with performance remaining consistent when tested using Hg2+ spiked into tap water, confirming robustness against matrix interferences. This optimized Q-TEPA-AgNPs nanosensor offers a promising, selective, and practical approach for mercury detection in complex aqueous environments.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...

