Correction of gas chromatography-mass spectrometry long-term instrumental drift using quality control samples over
Jie Yu1, Tong An1, Daifeng Chen2
1Technical Center, Shanghai Tobacco Group Co. Ltd., Shanghai, 201315, China.
Abstract:
Long-term instrumental data drift is a critical challenge for ensuring process reliability and product stability. In this study, we conducted 20 repeated tests on the smoke of six commercial tobacco products using gas chromatography-mass spectrometry (GC-MS) instrument over 155 days. We propose a simple, cost-effective, and reliable peak-area correction approach to address long-term data drift, especially on GC-MS data. Using 20 pooled quality control (QC) samples, we establish correction algorithm data set, and achieved reliable peak correction even for compositions exhibiting large fluctuations. Three algorithms - spline interpolation (SC), support vector regression (SVR), and Random Forest (RF) - were applied to normalise 178 target chemicals in 20 repeated measurements on six samples. Two key innovative approaches were introduced. First, we established a "virtual QC sample" by incorporating chromatographic peaks from all 20 QC results, via retention time and mass spectrum verification. This virtual QC served as the meta reference for analyzing and normalizing the test sample. Second, we took translated batch effects and injection order effects into two numerical indices in the algorithms, minimizing artificial parameterization of experiments. For chemical components found in the test samples but absent in the QC samples, normalisation was achieved using either adjacent chromatography peak for correction or by applying average correction coefficients derived from all QC data. Our results show that Random Forest algorithm provided the most stable and reliable correction model for long-term, highly variable data. Principal component analysis (PCA) and standard deviation analysis confirmed the robustness of the correction procedure. In contrast, models based on SC and SVR algorithms exhibited less stability with SC being the lowest. For data with large variation, SVR tends to over-fit and over-correct. This study shows that for long-term data measurements by GC-MS, periodic QC sample measurements combined with appropriate algorithm for correction can effectively compensate for long-term measurement variability, enabling reliable data tracking and quantitative comparison over extended periods.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Instrumentation