Related Experiment Video
Updated: Jan 10, 2026

An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
Robotic Intracorporeal Single-Stapled Anastomosis (RISS) is Associated with Lower Anastomotic Leakage Rates than the
Paulo Roberto Stevanato Filho1, Tiago Santoro Bezerra2, Tomas Mansur Duarte Miranda Marques2
1Colorectal Cancer Reference Center, A.C. Camargo Cancer Center, R. Professor Antônio Prudente, São Paulo, SP, Brazil. paulorstevanato@gmail.com.
Background:
Alternatives to the double-stapled (DS) technique for creating anastomoses after minimally invasive total mesorectal excision (TME) have been proposed to reduce complications and costs. Robotic intracorporeal single-stapled anastomosis (RISS) was developed as a technically intuitive approach. Standardizing such an intracorporeal robotic technique-which achieves adequate pelvic exposure, precise rectal transection, and secure anastomosis construction-may optimize outcomes, particularly anastomotic leakage (AL).
Methods:
A cohort study was conducted using our prospective institutional database and included patients < 80 years who underwent minimally invasive elective TME for extraperitoneal rectal cancer. Patients were allocated to the DS (abdominal stapled transection with double-stapled anastomosis) or RISS (robotic intracorporeal rectal transection with single-stapled anastomosis) groups. The exclusion criteria were nonrestorative procedures, intersphincteric resection, open surgery, and no indocyanine green perfusion assessments. The primary endpoint was 90-day clinical or radiological AL.
Results:
Among 380 TMEs, 167 met the inclusion criteria (71 RISS; 96 DS). The 90-day AL rate was significantly lower in the RISS group (5.6% vs. 16.7%; p = 0.032). Reintervention (1.4% vs. 10.4%; p = 0.025), overall morbidity (33.3% vs. 52.5%; p = 0.014), and length of stay (p < 0.0001) were lower following RISS. Multivariable analysis revealed that DS technique (odds ratio [OR] 3.3; p = 0.038) and comorbidities (OR 3.1; p = 0.028) independently predicted AL. Each additional stapler firing increased the risk of AL (OR 1.62; p = 0.016), and ≥3 firings predicted AL (OR 4.92; p = 0.011).
Conclusions:
Compared with DS, RISS was associated with lower anastomotic leakage, morbidity, and reintervention and shorter hospitalization. This standardized robotic approach is safe, reproducible, and potentially cost effective.
More Related Videos
12:45Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
Published on: February 12, 2022
07:22Surgical Robot-Assisted Transanal Specimen Extraction Radical Sigmoidectomy Without an Auxiliary Abdominal Incision
Published on: June 13, 2025