Small signal modelling and analysis of quasi Z-source direct matrix converter for wind energy conversion system

K T Maheswari1, C Kumar2, T Dharma Raj3

  • 1Electrical and Electronics Engineering, Bannari Amman Institute of Technology, Sathyamangalam, 638401, India.

Scientific Reports
|November 25, 2025
PubMed

Related Concept Videos

Wind Turbine Machine Models01:24

Wind Turbine Machine Models

In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
552
Three-Winding Transformers01:19

Three-Winding Transformers

Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
666
Simplified Synchronous Machine Model01:30

Simplified Synchronous Machine Model

The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
733
Source Transformation for AC Circuits01:11

Source Transformation for AC Circuits

The process of source transformation in the frequency domain entails the conversion of a voltage source, positioned in series with an impedance, into a current source that is parallel to an impedance, or the other way around. It is essential to maintain the following relationships while transitioning from one source type to another.
1.0K
Small-signal Diode Model01:18

Small-signal Diode Model

In analyzing the behavior of diodes in circuits, the relationship between the current through a diode and the voltage across it is of particular interest, especially when considering the effect of a direct current (DC) bias voltage. When applied, this DC bias influences the diode's operating point, known as the Q point, around which the current-voltage (I-V) characteristic of the diode exhibits exponential behavior. Introducing a small, time-varying signal on top of this bias aids in examining...
1.5K
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
489