Related Experiment Video
Updated: Jul 7, 2026

Visualization and Analysis of Blood Flow and Oxygen Consumption in Hepatic Microcirculation: Application to an Acute Hepatitis Model
Published on: August 4, 2012
Inter-institutional variability in kidney dosimetry during 177Lu-DOTATATE therapy in Japan
Noriaki Miyaji1, Kenta Miwa2,3, Kosuke Yamashita4
1Department of Radiological Sciences, School of Health Sciences Fukushima Medical University, 10-6 Sakaemachi, Fukushima-shi, 960-8516, Japan. noriaki.miyaji@gmail.com.
Abstract:
Dosimetry using SPECT/CT images enables personalized medicine by estimating absorbed doses and optimizing therapy. Differences in organ contouring and calculation algorithms contribute to inter-institutional variability, emphasizing the need for standardization. The present study aimed to investigate factors contributing to inter-institutional variability in kidney dosimetry in Japan. We analyzed four time points in SPECT/CT images of one male and one female patient each from the 177Lu SNMMI Dosimetry Challenge. Kidney volumes and absorbed doses were calculated at 10 Japanese institutes using their preferred organ-based (OLINDA 2.2, IDAC DOSE 2.1) and voxel-based (Voxel Dosimetry, RT-PHITS, MIM SurePlan MRT, OpenDose3D) software. Reference volumes of interest (VOI) files were distributed to assess the effect of contouring differences on kidney volumes and absorbed doses. Manual VOI contouring revealed substantial inter-institutional variability in kidney volumes, with coefficients of variation (%CVs) up to 16.9%. The reference VOIs reduced volume variability to ≤ 7.4%. Compared to manual VOIs, reference VOIs showed slightly increased doses in both patients with slightly reduced inter-institutional variability. The absorbed doses were generally higher in voxel- than organ-based dosimetry. The %CVs of the right and left kidneys in female patient decreased from 31.36% to 6.26% and 41.28%-3.97%, respectively. Variability in Kidney volume and absorbed doses significantly varied among Japanese institutes. Reference VOIs reduced volume variability but could not fully control dose differences. Voxel-based dosimetry can mitigate inter-institutional variability independent of contouring. Our findings emphasize the importance of algorithm standardization for reliable 177Lu-DOTATATE kidney dosimetry in Japan.
Related Concept Videos
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Dosage Regimen: Individualization
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant

