Related Experiment Video
Updated: Jan 7, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Precision TAVR quantification- AI-accelerated TAVR planning reduces assessment time by 80% in bicuspid aortic
Yu Mao1,2, Yang Liu1, Mengen Zhai1
1Department of Cardiovascular Surgery, Xijing Hospital Affiliated to Air Force Medical University, Xi'an, Shaanxi, China.
Aims:
Bicuspid aortic valve (BAV) stenosis complicates transcatheter aortic valve replacement (TAVR) planning, with no validated automated measurement algorithm available. We developed Cardioverse, the first fully automated deep learning algorithm for BAV anatomical assessment in TAVR planning.
Methods And Results:
We conducted a large-scale, multicenter retrospective study encompassing 1,147 consecutive patients with BAV undergoing TAVR across 16 high-volume Chinese centers (March 2019-February 2023). Cardioverse was trained on this cohort and evaluated in an internal (n = 437) and external (n = 110) validation cohorts. Our novel Cardioverse algorithm demonstrated exceptional segmentation performance across all anatomical targets with Dice similarity coefficients >0.97 for coronary cusps and ostia. Critically, the algorithm achieved unprecedented workflow efficiency gains: 80% reduction in assessment time [241.0 IQR (181.0, 297.0) vs. 1251.0 IQR (872.0, 1408.0) seconds], 85% reduction in user interactions [57.0 IQR (45.0, 78.0) vs. 382.5 IQR (285.5, 475.0) clicks], and 87% reduction in manual effort [7.5 IQR (4.8, 9.3) vs. 57.2 IQR (43.5, 68.4) meters mouse movement] compared to expert observers (P < 0.001). Importantly, accuracy was maintained across all BAV phenotypes with correlation coefficients >0.91 for all critical measurements, including annular dimensions, calcification quantification, and aortic root morphology assessment.
Conclusion:
Cardioverse transforms pre-TAVR assessment for BAV patients, offering a validated solution combining accuracy and efficiency. It reduces assessment time from over 20 min to < 5 min, addressing the need for standardized, rapid, and reliable BAV evaluation. Its robust performance across diverse BAV phenotypes makes it a crucial tool for enhancing TAVR planning consistency.
Clinical Trial Registration:
ClinicalTrials.gov Protocol Registration System (NCT05044338).
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of blood pressure in brachial artery(two-step method)