Related Experiment Video
Updated: Jan 7, 2026

Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation
Published on: July 3, 2015
Impact of Low-Dose CT Radiation on Gene Expression and DNA Integrity
Nikolai Schmid1, Vadim Gorte2, Michael Akers3
1Bundeswehr Institute of Radiobiology affiliated to Ulm University, Neuherbergstr. 11, 80937 Munich, Germany.
Abstract:
Computed tomography (CT) is a major source of low-dose ionizing radiation exposure in medical imaging. Risk assessment at this dose level is difficult and relies on the hypothetical linear no-threshold model. To address the response to such low doses in patients undergoing CT scans, we examined radiation-induced alterations at the transcriptomic and DNA damage levels in peripheral blood cells. Peripheral whole blood of 60 patients was collected before and after CT. Post-CT samples were obtained 4-6 h after scan (n = 28, in vivo incubation) or alternatively immediately after the CT scan, followed by ex vivo incubation (n = 32). The gene expression of known radiation-responsive genes (n = 9) was quantified using qRT-PCR. DNA double-strand breaks (DSB) were assessed in 12 patients through microscopic γ-H2AX + 53BP1 DSB focus staining. The mean dose-length product (DLP) across all scans was 561.9 ± 384.6 mGy·cm. Significant differences in the median differential gene expression (DGE) were detected between in vivo and ex vivo incubation conditions, implicating that ex vivo incubation masked the true effect in low-dose settings. The median DGE of in vivo-incubated samples showed a significant upregulation of EDA2R, MIR34AHG, PHLDA3, DDB2, FDXR, and AEN (p ranging from <0.001 to 0.041). In vivo, we observed a linear dose-dependent upregulation for several genes and an explained variance of 0.66 and 0.56 for AEN and FDXR, respectively. DSB focus analysis revealed a slight, non-significant increase in the average DSB damage post-exposure, at a mean DLP of 321.0 mGy·cm. Our findings demonstrate that transcriptional biomarkers are sensitive indicators of low-dose radiation exposure in medical imaging and could prove themselves as clinically applicable biodosimetry tools. Furthermore, the results underscore the need for dose optimization.
Related Concept Videos
Mutations
Chromosomal Alterations Are Large-Scale Mutations
While point mutations are changes in a single nucleotide in...
Mutagenicity and Carcinogenicity
Biological Effects of Radiation
Nucleotide Excision Repair
Cells are regularly exposed to mutagens—factors in the environment that can damage DNA and generate mutations. UV radiation is one of the most common mutagens and is estimated to introduce a significant number of changes in DNA. These include bends or kinks in the structure, which can block DNA replication or transcription. If these errors are not fixed, the damage can cause mutations, which in turn can result in cancer or disease depending on which sequences are...
Nucleotide Excision Repair
DNA Damage can Stall the Cell Cycle

