Related Experiment Video
Updated: Jan 7, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Transcatheter aortic valve replacement for severe aortic regurgitation in quadricuspid aortic valve: a case report
Abdullah Aljudaibi1, Mark Sonbol1, Haytham Allaham1
1University of Maryland Medical Center, Baltimore, MD, United States.
Abstract:
A 49-year-old woman with a congenital quadricuspid aortic valve presented in cardiogenic shock due to severe aortic regurgitation. She underwent transfemoral transcatheter aortic valve replacement with a 29 mm self-expanding prosthesis. The procedure was technically successful with minimal paravalvular leak and significant symptomatic improvement. However, her long-term course was complicated by medication nonadherence, valve thrombosis, thromboembolic coronary events, and progressive heart failure. This case highlights the anatomical and technical challenges of transcatheter valve therapy in non-tricuspid anatomy, including annular sizing and valve anchoring without calcification, and underscores the critical importance of post-procedural anticoagulation adherence and meticulous follow-up to prevent thrombotic complications.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Aortic Regurgitation IV: Nursing Management
Mitral Regurgitation III: Medical Management