Related Experiment Video
Updated: Jan 13, 2026

Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Extensive Backbone Cleavage Coverage of Intact Proteoforms in a Mass Range of 10-70 kDa by Integrating Electron,
Qianjie Wang1,2, Qianyi Wang1, Rafael D Melani3
1Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, United States.
Abstract:
Capillary zone electrophoresis (CZE)-tandem mass spectrometry (MS/MS) has been documented as a useful tool for top-down proteomics (TDP). However, CZE-MS/MS-based TDP typically has limited backbone cleavage coverage for identified proteoforms due to the use of traditional collision-based fragmentation methods (i.e., higher-energy collisional dissociation, HCD). Here, for the first time, we coupled CZE to an Orbitrap Ascend Tribrid mass spectrometer to investigate the performance of collision-, electron-, and photon-based fragmentation methods and their combinations for boosting the backbone cleavage coverage of proteoforms during the electrophoretic time scale using a standard protein mixture covering a mass range of about 10-70 kDa. CZE-MS achieved reproducible measurement of six proteins including three insulin-like growth factor (IGF) proteoforms with different modifications. Systematic investigations of HCD, electron-transfer dissociation (ETD), electron-transfer/HCD (EThcD), and ultraviolet photodissociation (UVPD) during CZE-MS/MS analysis revealed distinct yet complementary fragmentation characteristics. ETD, EThcD, and UVPD, in general, provided higher backbone cleavage coverage than HCD. The integration of HCD, ETD, EThcD, and UVPD data offered 67 and 98% sequence coverage for carbonic anhydrase (a 30 kDa protein) and thioredoxin (a 12 kDa protein), which is 158 and 100% higher than that produced by HCD alone. Adding internal fragments further boosted the backbone cleavage coverage substantially, for example, from 67 to 94% for 30 kDa carbonic anhydrase and from 21 to 82% for 50 kDa protein AG. The results demonstrate the capability of CZE-MS/MS with the integration of various fragmentation techniques for comprehensive characterization of proteoforms in a wide mass range.
Related Concept Videos
Tandem Mass Spectrometry
Mass Spectrometry: Molecular Fragmentation Overview
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
Mass Spectrometry: Overview
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example, the...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrum: Interpretation

