Related Experiment Video
Updated: Jan 13, 2026

Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Comprehensive Analysis of Chlorine-Induced Aging in High-Density Polyethylene: Insights into Structural, Thermal, and
Elena-Emilia Sirbu1, Maria Tănase2, Alin Diniță2
1Chemistry Department, Petroleum-Gas University of Ploiești, 100680 Ploiesti, Romania.
Abstract:
This study investigates chlorine-induced aging of high-density polyethylene (HDPE) through a 3 × 3 factorial matrix combining three temperatures (20, 40, 60 °C) and three chlorine concentrations (5, 10, 20 ppm) over 45 days. Tensile tests revealed progressive embrittlement, with elongation at break decreasing sharply under severe aging; samples exposed to 60 °C and 20 ppm exhibited premature brittle failure despite peak stresses remaining near ~22 MPa. XRD results showed a reduction in crystallinity from 67.07% (reference) to 61.06-61.31% under the most aggressive conditions, accompanied by a decrease in crystallite size from 5.60 nm to 2.10-2.50 nm. FTIR analysis confirmed oxidation through increased carbonyl absorption at 1716 cm-1 and new bands at 1608-1635 cm-1. TGA revealed substantial thermal deterioration, with T5% falling from 450 °C (reference) to 327 °C at 60 °C/20 ppm, along with an additional degradation peak at 398 °C. DSC showed a melting temperature decrease from 136.32 °C to 131.67 °C and an increase in crystallinity from 41.07% (unexposed sample) to 59.19% (60 °C/20 ppm). Statistical analysis of the results established that degradation is governed by different dominant factors depending on the measured property: Chlorine concentration was found to be the dominant factor for XRD crystallinity and thermal decomposition T5%, confirming that surface structural damage and early molecular weight loss are driven primarily by chlorine-induced oxidation. Conversely, DSC crystallinity was governed primarily by temperature, reflecting thermally driven molecular reorganization within the bulk material. Overall, chlorine exposure, amplified by temperature, accelerates chemical oxidation, structural degradation, and mechanical embrittlement, reducing the long-term reliability of HDPE in chlorinated water systems. The findings provide critical data for predicting the service life and informing material selection for HDPE components used in high-temperature or high-chlorine water distribution systems.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
07:53Cutting Procedures, Tensile Testing, and Ageing of Flexible Unidirectional Composite Laminates
Published on: April 27, 2019
Related Concept Videos
Polymer Classification: Architecture
Free-Radical Chain Reaction and Polymerization of Alkenes
Radical Chain-Growth Polymerization: Chain Branching
Types of Step-Growth Polymers: Polyesters
Polyesters are commonly prepared from terephthalic acid and ethylene glycol; the crude product is known as poly(ethylene terephthalate) or PET. However, polyesters are synthesized industrially by transesterification of dimethyl terephthalate with ethylene glycol at 150 °C. The two reactants and the polymer...
Polymer Classification: Stereospecificity
Thermal Strain