Related Experiment Video
Updated: Jan 20, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Strategic Transcatheter Aortic Valve Replacement in Patients With Protruding Left Coronary Artery Stents
Yuji Manabe1, Hiroyuki Kiriyama1, Tatsuki Furusawa1
1Department of Cardiovascular Medicine, The University of Tokyo, Tokyo, Japan.
Background:
Transcatheter aortic valve replacement is challenging in patients with coronary artery stents protruding into the aorta. While there have been a few reports using balloon-expandable valves with unique techniques, there are no reports using self-expandable valves (SEVs).
Case Summary:
A 94-year-old man with a protruding left main tract stent into the aorta underwent transcatheter aortic valve replacement with SEV, taking into consideration the interference with the coronary artery ostium. Through coronary artery protection and postdilatation of the coronary ostium, the transcatheter heart valve (THV) was able to be safely implanted and coronary blood flow was preserved, although the commissure tab of the THV was in close proximity to the coronary ostium.
Discussion:
The cell size and the commissure alignment of the THV are of particular concern when implanting SEVs in patients with protruding coronary stent.
Take-Home Message:
SEV implantation can be a safe option in patients with protruding coronary stents.
Related Concept Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery (ALCAPA)
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
08:50Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement