Single photon emitters in hBN: Limitations of atomic resolution imaging and potential sources of error
David Lamprecht1, Shrirang Chokappa2, Alissa M Freilinger3
1Institute for Microelectronics, TU Vienna, Gusshausstrasse 27-29, Vienna, 1040, Austria; University of Vienna, Faculty of Physics, Boltzmanngasse 5, Vienna, 1090, Austria.
Abstract:
There is a growing interest in identifying the origin of single-photon emission in hexagonal boron nitride (hBN), with proposed candidates including boron and nitrogen vacancies as well as carbon substitutional dopants. Because photon emission intensity often increases with sample thickness, hBN flakes used in these studies commonly exceed 30 atomic layers. To identify potential emitters at the atomic scale, annular dark-field scanning transmission electron microscopy (ADF-STEM) is frequently employed. However, due to the intrinsic AA' stacking of hBN with vertically alternating boron and nitrogen atoms, this approach is complicated even in few-layer systems. Here, we demonstrate using STEM image simulations and experiments that, even under idealized conditions, the intensity differences between boron- and nitrogen-dominated columns and carbon substitutions become indistinguishable at thicknesses beyond 17 atomic layers (ca. 6 nm). While vacancy-type defects can remain detectable at somewhat larger thicknesses, also their detection becomes unreliable at thicknesses typically used in photonic studies. We further show that common residual aberrations, particularly threefold astigmatism, can lead to artificial contrast differences between columns, which may result in misidentification of atomic defects. We systematically study the effects of non-radially symmetric aberrations on multilayer hBN and demonstrate that even small residual threefold astigmatism can significantly distort the STEM contrast, leading to misleading interpretations.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Structure
Atomic Mass
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error