Related Experiment Video
Updated: Jan 24, 2026

06:23
Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo
Published on: August 4, 2018
9.2K
Bipolar coagulation techniques versus the clamp-crush technique for elective liver resection
Mario Kopljar1,2, Roman Pavić1,3, Zrinko Madžar2
1Faculty of Medicine Osijek, Josip Juraj Strossmayer University of Osijek, Osijek, Croatia.
The Cochrane Database of Systematic Reviews
|January 23, 2026
Summary
This review compares bipolar coagulation and clamp-crush techniques for liver resection in children and adults. It aims to determine the benefits and harms of each surgical method for elective liver resections.
Area of Science:
- Hepatobiliary surgery
- Surgical techniques
- Oncology
Background:
- Liver resection is a critical procedure for treating liver tumors and other conditions.
- Minimizing blood loss and complications during liver resection is paramount.
- Different hemostatic techniques are employed to control bleeding from the liver parenchyma.
Purpose of the Study:
- To systematically review and synthesize evidence comparing bipolar coagulation and clamp-crush techniques in liver resection.
- To evaluate the safety and efficacy of these two hemostatic methods.
- To assess outcomes in both pediatric and adult patients undergoing elective liver resection.
Main Methods:
- Cochrane systematic review methodology.
- Inclusion of randomized controlled trials and relevant observational studies.
- Data extraction on operative outcomes, including blood loss, operative time, and complications.
Main Results:
- The review protocol outlines the planned analysis of benefits and harms.
- Specific results will be determined upon completion of data synthesis.
- Anticipated outcomes include comparisons of hemostatic effectiveness and patient recovery.
Conclusions:
- The findings will inform surgical practice regarding optimal hemostatic techniques for liver resection.
- Evidence-based recommendations will be provided for bipolar coagulation versus clamp-crush methods.
- This review aims to improve patient outcomes in liver surgery.
More Related Videos
Related Concept Videos
Coagulation
1.3K
Colloidal solids are solid particles suspended in solution. They are usually negatively charged, attracting a compact primary layer of positively charged ions, which attract more counterions to form an electrical double layer. Electrostatic repulsion between the charged double layers prevents the particles from colliding, stabilizing the colloids. These solids are often undesirable because they can contain toxins that are difficult to remove. Coagulation is a technique that helps aggregate and...
1.3K
Coagulation
9.8K
The coagulation phase is a critical part of the body's process to prevent blood loss following injury to blood vessels. It involves chemical reactions that form a clot to seal the injured area. The clotting process begins shortly after injury, within 15-20 seconds for severe damage and 1-2 minutes for minor injuries.
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
9.8K
Bipolar Disorder
663
Bipolar disorder is a chronic mental health condition marked by significant mood fluctuations, including episodes of mania and depression. Elevated energy levels, heightened mood or irritability, impulsive behavior, reduced sleep needs, rapid speech, racing thoughts, inflated self-esteem, and distractibility characterize mania. Individuals with bipolar disorder often alternate between depressive and manic states, with periods of emotional stability lasting an average of six months to a year.
663
Bipolar Junction Transistor
1.5K
Bipolar Junction Transistors (BJTs) are essential elements in electronic circuits, playing a crucial role in the functionality of amplifiers, memories, and microprocessors. These transistors can be designed as NPN or PNP based on their doping patterns. They consist of three layers: the emitter, base, and collector. The configuration of these layers and their respective doping levels—with N-type or P-type impurities—define the transistor's type and its operational...
1.5K
Simple Staining Technique
3.4K
OverviewStaining techniques in microscopy enhance the visualization of microorganisms by increasing contrast and allowing the differentiation of cellular structures. Simple staining is one of the fundamental methods used to observe the basic morphological characteristics of microorganisms, including their size, shape, and arrangement. This method relies on the application of a single dye to stain the entire cell, producing a clear contrast between the cell and the background.FixationFixation is...
3.4K
Differential Staining Technique
2.1K
Differential staining is an essential microbiological technique that exploits variations in cell wall structures to classify and identify microorganisms. It facilitates the distinction of bacteria, aiding in diagnostic and research applications. Two of the most widely used differential staining methods are Gram staining and acid-fast staining, both of which rely on the chemical and structural differences in bacterial cell walls.Gram Staining TechniqueGram staining differentiates bacteria by...
2.1K

