Related Experiment Video
Updated: Jan 27, 2026

11:19
Robotic Myotomy and Partial Fundoplication for Achalasia
Published on: August 11, 2023
1.9K
Fatal Steam Pop Complicating Investigational SESAME Transcatheter Myotomy Using Off-the-Shelf Equipment
Robert J Lederman1, Adam B Greenbaum2, Rim N Halaby1
1Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD (R.J.L., R.N.H., A.M.S., J.M.K., C.G.B., T.R.).
Circulation. Cardiovascular Interventions
|January 26, 2026
Summary
No abstract available in PubMed .
Related Concept Videos
Leveling Equipment
403
As leveling involves measuring vertical distances relative to a horizontal line of sight, it requires a graduated rod, called a level rod, for vertical measurements and an instrument called a level for a horizontal sight line. A level includes a high-powered telescope with a mechanism for leveling to ensure the line of sight is horizontal when the bubble in the spirit level is centered. Leveling rods, made of wood, metal, or fiberglass, are graduated in feet or meters and commonly used in two-...
403
Personal Protective Equipment
2.2K
Personal protective equipment (PPE) is unique clothing or equipment worn by an employee to minimize or prevent exposure to infectious agents. PPE creates a barrier between the employee and the infectious materials. PPE must be readily available in the patient care area. PPE includes gloves, gowns and aprons, masks and respirators, goggles, face shields, shoes, and headcovers:
2.2K
Diabetes: Symptoms, Diagnosis, and Complications
2.1K
For most patients, experiencing several weeks of polyuria, polydipsia, fatigue, and significant weight loss may indicate the presence of diabetes. Furthermore, adults displaying the phenotypic appearance of type 2 diabetes (particularly those who are obese and not initially insulin-requiring), may have islet cell autoantibodies, suggesting autoimmune-mediated β cell destruction and a diagnosis of latent autoimmune diabetes of adults (LADA). The categorization of glucose homeostasis is...
2.1K
Pneumonia III: Complications and Assessment
822
Pneumonia poses the potential for numerous complications that warrant consideration. These complications include the following:
822
Hemodialysis II: Procedure and Complications
755
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
755
Equipments Used to Measure Body Temperature
1.8K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.8K

