Self-Adhesive Mask and Homemade Carbon Ink: Turning Unusable Screen-Printed Electrodes into a New Voltammetric Sensor

Gabriel Chitolina-Rodrigues1, Adriano Rogerio Silva Lima1, Duane Bortot1

  • 1Departamento de Química, Universidade Federal de Santa Catarina, Campus Universitário Trindade, 88040-900 Florianópolis, SC, Brazil.

ACS Omega
|January 26, 2026
PubMed
Abstract

Related Concept Videos

Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
1.6K
Adhesion01:14

Adhesion

Adhesion occurs when one type of molecule is attracted to a different molecule. Water exhibits adhesive properties in the presence of polar surfaces, such as glass or cellulose in plants. For instance, when water is poured into a glass, the positively charged hydrogen molecules of water are more attracted to the negatively charged oxygen molecules in the silica than to the oxygen in neighboring water molecules.
Capillary action is a result of water’s adhesive tendencies. When a narrow...
43.9K
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
1.6K
Administering Oxygen by Mask01:30

Administering Oxygen by Mask

Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
2.3K
Masking and Demasking Agents01:19

Masking and Demasking Agents

EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
3.5K
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
1.2K