Related Experiment Video
Updated: Jan 28, 2026

Planar and Three-Dimensional Printing of Conductive Inks
Published on: December 9, 2011
Self-Adhesive Mask and Homemade Carbon Ink: Turning Unusable Screen-Printed Electrodes into a New Voltammetric Sensor
Gabriel Chitolina-Rodrigues1, Adriano Rogerio Silva Lima1, Duane Bortot1
1Departamento de Química, Universidade Federal de Santa Catarina, Campus Universitário Trindade, 88040-900 Florianópolis, SC, Brazil.
None:
Screen-printed carbon electrodes (SPCEs) are widely employed in sensing due to their low cost, especially the model DRP-110. However, their disposable nature limits their long-term applications. In this work, we present a sustainable methodology for recovering the electrode model DRP-110-U75. Unusable SPCEs were made usable again after employing a stencil-printing approach. After recuperating the electrodes (Re-SPCE), characterization experiments upon the Re-SPCEs have indicated similar morphological aspects and catalytic ability when compared to as-purchased SPCEs. As a proof of concept, voltammetric analysis of dopamine (DOP) in artificial urine and tryptophan (TRP) in supplement capsules was successfully employed, exhibiting limits of detection of 2.15 and 0.2 μmol L-1 for DOP and TRP, respectively. These results confirm that the proposed method can extend the life cycle of SPCEs.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
07:42Inkjet Printing All Inorganic Halide Perovskite Inks for Photovoltaic Applications
Published on: January 22, 2019
Related Concept Videos
Voltammetric Techniques: Pulse Voltammetry
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Voltammetric Techniques: Cyclic Voltammetry
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
Voltammetric Techniques: Linear-Scan (E vs Time)