Related Experiment Video
Updated: Jan 28, 2026

Author Spotlight: Integrating Mechanical and Biological Analysis in Tendinopathy Research
Published on: March 1, 2024
Optimization of Actuator Stiffness and Actuation Timing of a Passive Ankle Exoskeleton: A Case Study Using a
Jania Williams1, Cody P Anderson2, Arash Mohammadzadeh Gonabadi1,3
1Department of Biomechanics and Center for Research in Human Movement Variability, University of Nebraska at Omaha, Omaha, NE 68182, USA.
Objective:
A modeling and simulation tool, OpenSim, was used to determine the optimal relationship between actuator stiffness and actuation timing of a passive ankle exoskeleton for reducing metabolic costs during walking. We hypothesized that the absolute minimum in total metabolic cost would exist at an actuation timing of 15% of stance and at a spring stiffness of 7.5 kN/m. We also hypothesized that a local minimum in total metabolic cost would exist at an actuation timing of 50% of stance.
Methods:
Bilateral kinematics and kinetics data were collected on a healthy male walking overground wearing his regular tennis shoe. The passive ankle exoskeleton geometry and the spring actuator were integrated into the OpenSim model. Simulations were performed for every combination of 25 spring stiffnesses ranging from 5.5 kN/m to 17.5 kN/m (increments of 0.5 kN/m) and 10 actuation timings ranging from 15% to 60% of stance (increments of 5%). Total energy expenditure was calculated as the sum of the energy expenditure of all the muscles in the model.
Results:
The greatest reduction in energy consumption (-2.67%) was observed at an actuation timing of approximately 15% of the stance phase with a spring stiffness of ~5.5 kN/m. A quadratic relationship between spring stiffness and energy consumption was identified (R2 = 0.99), with an optimal stiffness of approximately 5.5 kN/m minimizing the energy cost.
Conclusions:
Our findings suggest that OpenSim effectively predicts optimal exoskeleton parameters, supporting personalized assistance to improve energy efficiency and rehabilitation outcomes.
Related Concept Videos
Ankle Joint
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Model Approaches for Pharmacokinetic Data: Physiological Models
Model Approaches for Pharmacokinetic Data: Compartment Models
Two primary types of compartment models are recognized: mammillary and catenary. The more...
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...