Cyclic Fatigue Resistance and Phase Transformation Behavior of SlimShaper and SlimShaper PRO NiTi Instruments: A
Cristina Scolaro1, Francesco Puleio2, Andrea Sili1
1Department of Engineering, University of Messina, 98166 Messina, Italy.
Abstract:
Objectives: This study compared the cyclic fatigue resistance and the mechanical, thermal, and metallurgical characteristics of SlimShaper® and SlimShaper PRO® instruments. Both sequences include three instruments (ZS1-ZS3) with identical geometries, although SlimShaper PRO features an apically modified thermal treatment. Methods: Cyclic fatigue tests were performed using a standardized metallic guide with a 45° curvature, on six instruments of each sequence type. Fractured segments were measured, and fracture surfaces were analyzed using optical microscopy and Scanning Electron Microscopy (SEM). Elemental composition was assessed by Energy-dispersive Spectroscopy (EDS), while Differential Scanning Calorimetry (DSC) was used to determine transformation temperatures and enthalpy. Results: ZS1 and ZS1 PRO exhibited comparable cyclic fatigue resistance, whereas ZS2 and ZS3 showed significantly higher resistance than their PRO counterparts. SlimShaper PRO® instruments fractured with segments approximately 0.5-1 mm longer. EDS confirmed that both instruments were made of NiTi, with minor differences in surface composition, while DSC demonstrated similar enthalpy values but distinct transformation ranges. At room temperature (27 °C), SlimShaper® ZS2 remained predominantly martensitic, whereas ZS2 PRO could be partially austenitic, explaining its observed reduced fatigue resistance. The results of the DSC allowed to deduce the microstructure and thus the fatigue behavior at the temperature of the oral cavity. Conclusions: SlimShaper ZS2 and ZS3 showed significantly greater cyclic fatigue resistance than their PRO counterparts, while DSC analysis revealed distinct differences in phase transformation behavior that explain their mechanical performance.
Related Concept Videos
Instrument Transformers
Fatigue
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Phase Transitions: Sublimation and Deposition
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...