Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Utility of Dynamic 68Ga-DAZA-PET/CT for Bile Leak Localization After Liver Transplantation: First Clinical
Anke Werner1, Oliver Rohland2, Julia Greiser1
1Department of Nuclear Medicine, Jena University Hospital, 07747 Jena, Germany.
[68Ga]Ga-TEoS-DAZA-PET/CT successfully located bile leaks after liver transplantation (LT) in all patients. This novel imaging technique offers a safe and feasible option for precise anatomical localization when conventional methods fail.
Area of Science:
- Nuclear Medicine
- Radiopharmaceuticals
- Medical Imaging
Background:
- Biliary complications, particularly bile leaks, are frequent causes of morbidity after liver transplantation (LT).
- Conventional imaging methods (ultrasound, CT, MRCP, endoscopy) often struggle to pinpoint complex or peripheral bile leaks.
- Accurate localization is crucial for effective treatment and improved patient outcomes.
Purpose of the Study:
- To assess the feasibility and efficacy of [68Ga]Ga-TEoS-DAZA-PET/CT for non-invasive localization of bile leaks post-liver transplantation.
- To evaluate [68Ga]Ga-TEoS-DAZA-PET/CT as a complementary diagnostic tool in cases with inconclusive conventional imaging.
Main Methods:
- Five male patients with suspected bile leaks and inconclusive prior imaging underwent dynamic [68Ga]Ga-TEoS-DAZA-PET/CT scans.
- The tracer was synthesized under Good Manufacturing Practice (GMP) conditions and administered.
- Imaging was performed for 60 minutes, with findings classified using the Nagano classification.
Main Results:
- [68Ga]Ga-TEoS-DAZA-PET/CT accurately detected and anatomically localized bile leaks in all five patients.
- Identified leak sites included the liver resection surface, central bile ducts, bilioenteric anastomosis, and biliary drainage exit.
- Findings guided subsequent interventions (surgery or endoscopy) in four patients, with one improving conservatively. No adverse events were reported.
Conclusions:
- [68Ga]Ga-TEoS-DAZA-PET/CT is a feasible and safe imaging modality for localizing bile leaks after LT.
- Its ability to visualize antegrade biliary flow, coupled with high resolution and no contraindications, makes it valuable when conventional imaging is insufficient.
- Further research is needed to confirm its diagnostic utility for postoperative and post-traumatic biliary injuries.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
08:45New Thrombectomy Technique for Total Portal Vein Thrombosis in Liver Transplantation
Published on: June 27, 2025
Related Concept Videos
Bile
Bile is released when dietary fats enter...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
What is an Experiment?