Related Experiment Video
Updated: Jan 29, 2026

Analysis of Non-Human Primate Pancreatic Islet Oxygen Consumption
Published on: December 18, 2019
Low Responsiveness of Macroencapsulated Human Islets Towards Glucose Challenge Despite Excellent Survival in
Daniel Brandhorst1,2, Heide Brandhorst1,2, Daniel A Domingo-Lopez3
1Islet Transplant Research Group, Nuffield Department of Surgical Sciences, University of Oxford, Oxford OX3 9DU, UK.
Abstract:
Islet encapsulation has the potential to enable transplantation without requirement for life-long immunosuppression. The period between implantation and revascularisation is most harmful for encapsulated islets as they receive nutrients and oxygen exclusively via diffusion. This critical time gap must be bridged with a temporary oxygen supply to prevent inflammation and apoptosis. Hence, we compared the efficiency of individual components of an oxygen-delivering matrix (hyaluronic acid (HA); HA + perfluorodecalin nanoemulsion; HA + perfluorodecalin nanoemulsion + oxygen) to provide a substitute for the extracellular matrix and to facilitate human islet survival. The islets were loaded into silicone-based macroencapsulation devices with multi-scale porous membranes designed to optimise revascularisation. Four to five days of normoxic culture revealed that non-oxygen-charged nanoemulsion prevented islet disintegration but did not reduce necrosis or apoptosis. Oxygen supply decreased the generation of reactive oxygen species and chemokines, thereby increasing islet yield. Stimulated insulin secretion of encapsulated islets was marginal and severely delayed. Islets incubated in oxygen-precharged nanoemulsion were characterised by the highest stimulation index. These data suggest that islet survival in macroencapsulation devices can be optimised with a multi-functional matrix providing mechanical support and temporary oxygen supply to reduce the production of pro-inflammatory mediators. Suitable oxygen delivery systems with an extended life span must identified before in vivo experiments can be undertaken.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Microsoft Excel: Plotting Mean, SD, and SE
First, calculate the mean, SD, and SE of your data. The mean is obtained using the formula `=AVERAGE(range)`, while SD can be calculated with `=STDEV.P(range)` for a population or `=STDEV.S(range)` for a sample. SE is calculated as `=SD/SQRT(n)`, where `n` is the sample size.
To plot these values, use a bar...
Microsoft Excel: Student's t-Test
To conduct a t-test in Excel, use the T.TEST function or the "Data...

