Related Experiment Video
Updated: Feb 10, 2026

Cell-Free Dot Blot as a Practical and Adaptable Immunoassay Platform for the Detection of Antibody Response in Human and Animal Sera
Published on: May 23, 2025
Catch-and-Display Immunoassay as an Accessible Platform for Digital Biomarker Detection
Yuxuan Liu1, Sam Walker2, Michael Klaczko3
1Materials Science, University of Rochester, Rochester, NY 14627, United States.
None:
Digital immunoassays provide exceptional analytical sensitivity for detecting low-abundance biomarkers, but their broad adoption is limited by practical barriers. Commercial platforms are prohibitively expensive for routine use by individual laboratories, and laboratory-scale concepts typically describe specialized biosensors and sophisticated workflows. Here, we introduce a nanomembrane-based Catch-and-Display Immunoassay (CAD-IA) as an accessible digital immunoassay for common laboratory settings. In CAD-IA, fluorescent nanoparticles are "captured" by the nanoscale pores of ultrathin silicon nitride membranes through a pipette powered filtration. The captured nanoparticles serve as optically isolated 'hotspots' for fluorescent immunocomplex formation when target antigen is present. Co-localization of the fluorescent particles and fluorescent immunocomplexes are then "displayed" and quantified by standard confocal microscopy to generate digital signals. CAD-IA is implemented using the μSiM-DX (microfluidic device featuring an ultrathin silicon membrane for diagnostics) platform, which is manually assembled from mass produced, cost-effective components. Using the traumatic brain injury (TBI) biomarker S100B as a model, we demonstrate that CAD-IA provides consistent digital outputs and linear quantification with a dynamic range of at least two orders of magnitude when digital and analog analysis are combined on the same image sets. We further demonstrate that the assay maintains linearity in serum matrices and achieves suitable sensitivity (LoD = 0.02 μg/mL) for clinically relevant diagnostic with the addition of tyramide signal amplification (TSA). While further optimization of CAD-IA is possible, these results constitute a proof-of-concept demonstration of a novel digital immunoassay that is accessible to most laboratory environments.
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Social Foundations of Self IV: Self in Digital Communication
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...

