Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes
Ali Maziz1, Clement Cointe1, Benjamin Reig1
1Laboratoire d'Analyse et d'Architecture des Systemes-Centre National de la Recherche Scientifique (LAAS-CNRS), 7 Avenue du Colonel Roche, 31400 Toulouse, France.
Abstract:
Poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT:PSS) is widely used to fabricate conductive organic coatings for electrodes in electrophysiology. As these devices move toward clinical translation, establishing sterilization methods that preserve their functional properties is essential. Ethylene oxide (EtO) is routinely used for sterilizing heat- and moisture-sensitive medical devices due to its high penetration efficiency and low thermal load. However, the absence of systematic studies evaluating its impact on PEDOT:PSS raises concerns about the compatibility of EtO sterilization with organic electrophysiology interfaces. Here, we report the first comprehensive evaluation of EtO sterilization on PEDOT:PSS electrodes electrochemically deposited onto cortical interfaces designed for intraoperative monitoring and stimulation. EtO exposure induced only minimal changes in surface topography, with no detectable alteration of the electrical or electrochemical performance of the electrodes. Impedance spectroscopy, cyclic voltammetry, and charge-injection capacity measurements all revealed that EtO-treated electrodes retained properties comparable to untreated controls. Moreover, EtO-sterilized PEDOT:PSS coatings demonstrated robust long-term stability under accelerated lifetime testing, exhibiting negligible degradation over extended operation. These findings demonstrate that EtO sterilization is fully compatible with PEDOT:PSS-based bioelectronic interfaces and constitutes a viable pathway toward their safe and effective integration into clinical electrophysiology. This work represents an important step toward translating organic conducting polymer technologies into real-world biomedical applications.
Related Concept Videos
Standard Electrode Potentials
Oxidation Numbers
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Impact of Groups on Groups
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...