Simultaneous Use of Continuous Glucose Monitoring (CGM) Systems and the Remote Electrical Neuromodulation (REN)
Yara Asmar1, Alit Stark-Inbar1, Maria Carmen Wilson2
1Theranica, Netanya 4250438, Israel.
Abstract:
Background/Objectives: Migraine and diabetes mellitus are highly prevalent chronic diseases, and their comorbidity presents management challenges, particularly when wearable medical technologies are used concurrently. Remote electrical neuromodulation (REN; Nerivio®) is an FDA-cleared non-pharmacological migraine therapy, and continuous glucose monitoring (CGM) systems are widely used in diabetes care. However, the safety and compatibility of simultaneous co-use have not yet been evaluated. This technical compatibility study aimed to assess whether REN operation affects CGM performance or interferes with glucose measurement integrity in diabetic adults. Methods: Twenty-one adults with diabetes using Dexcom G6/G7 or FreeStyle Libre 2/3 participated in a single-arm interventional study. During a 45 min session, participants operated the REN and CGM devices simultaneously on their smartphones, and the REN device was paused three times to compare CGM readings between REN ON and RED OFF conditions. The primary outcome was the mean absolute relative difference (MARDREN ON/OFF), evaluated against a prespecified 5% threshold. Statistical analysis included the Wilcoxon test, with subgroup analysis by the CGM device family. Results: The median MARDREN ON/OFF across all participants was 1.61% (IQR 0.84-2.44%), significantly below the 5% threshold (p < 0.001). All participants achieved MARDREN ON/OFF < 5%. Subgroup analyses were consistent: the median MARDREN ON/OFF was 1.70% (IQR 0.90-2.45%) for Dexcom and 1.05% (IQR 0.83-1.50%) for Abbott. No technical interference, Bluetooth disruptions, missed data transmission, or adverse events were observed. Conclusions: Simultaneous use of Nerivio® REN and CGM systems in adults with diabetes is compatible and safe, with no evidence of interference or significant deviations in glucose readings. These findings support the integrated and reliable use of REN and CGM wearables in adults with diabetes managing comorbid conditions.
Related Concept Videos
Electrical Systems
To derive the transfer function, consider an RLC...
Electric Field of a Continuous Line Charge
In calculations of electric fields, symmetry is of great use. For example, while calculating electric fields of continuous charge distributions.
Consider a line element with a...
Oral Drug Delivery Systems: Continuous-Release Systems
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...