Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Shear wave elastography for assessing rectus femoris stiffness: a study on the interaction and reliability of body
Yating Wang1,2, Tianqi Wang2, Xuemei Liu2
1Department of Ultrasound, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
Objective:
To employ shear wave elastography (SWE) to assess changes in stiffness and reliability in the vastus rectus muscle of healthy adults across different posture-contraction states. We analyzed the main effects and interactions of posture and contraction intensity on shear wave velocity (SWV) and explored its relationship with relevant biological parameters.
Methods:
We recruited healthy participants, with two observers using SWE technology to measure the SWV of the vastus rectus muscle in the supine (relaxation, plantarflexion, and dorsiflexion) and sitting (relaxation, leg elevated, and 5-kg loading) positions. Intra- and interobserver reliabilities were evaluated using the intraclass correlation reliability. Repeated-measures analysis of variance was used to examine the main effects and interactions of posture and contraction state on SWV. Additionally, correlations between the SWV and rectus femoris thickness (RFthick), circumference (RFcirc), cross-sectional area (RFcsa), and contraction index (RFci) were calculated.
Results:
Forty-six adults (11 males and 35 females) completed the study. SWE measurements demonstrated high intra- and interobserver reliability across all conditions (ICC >0.80). Two-way repeated-measures analysis of variance revealed significant main effects of body position (F (1,45) = 58.85, P < 0.001, ηp 2 = 0.567) and contraction state (F (1.76, 78.97) = 104.23, P < 0.001, ηp 2 = 0.777), with a significant interaction (F (2,44) = 24.66, P < 0.001, ηp 2 = 0.459). The SWV changes were more pronounced in the 5-kg load position (45.9%). Ultrasound parameters (RFthick, RFcirc, RFci) varied significantly across conditions (P < 0.05), whereas the RFcsa did not (P = 0.194). The SWV was positively correlated with specific architectural parameters, depending on posture, but not with demographic variables (P > 0.05).
Conclusion:
This study establishes a methodological basis for assessing the stiffness of the RF, identifying posture and contraction as key factors. Our findings underscore the need for standardized measurement and support the future application of SWE in biomechanics, sports, and rehabilitation.
More Related Videos
09:10The Lower Body Positive Pressure Treadmill for Knee Osteoarthritis Rehabilitation
Published on: July 22, 2019
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Reliability and Validity
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...