Related Experiment Video
Updated: Feb 17, 2026

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
TPE-based cationic AIEgen with large stokes shift enables detection of blood anti-coagulator heparin with high
Sandhya Vilas Yadav1,2, Sandip Kumar Deb3, Partha Sarathi Addy3
1Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai, 400085, India.
Abstract:
In this present study, a thiazolium based tetraphenyl ethylene derivative (TPET) was developed for the sensitive and selective detection of heparin (Hp), exploiting the aggregation-induced emission (AIE) feature of TPE. The probe, TPET remains weakly emissive in its dispersed monomeric form but exhibits a pronounced fluorescence "turn-on" response upon interaction with Hp. The probe, TPET due to its inherent cationic nature, experiences a strong electrostatic interaction at the vicinity of polyanionic Hp, which eventually helps TPE derivative to form aggregated species, leading to fluorescence light up response via aggregation-induced emission (AIE). This strategy allows for reliable detection of Hp down to 20.2 nM in aqueous solution. Furthermore, ruggedness of the dye-Hp complex across a broad pH range, showcasing the excellent stability and environmental robustness of the TPE-based system. Importantly, the probe demonstrates excellent preferential response towards heparin compared to other glucosamines and bio-analytes, encouraging its utilization for Hp detection even in complex biomedia. The system achieved a low limit of detection (LOD) of 614.9 nM and 78.4 nM in 25% artificial urine and 0.5% human serum, respectively. Additionally, the dye-Hp complex can also be applied for the detection of Hp antidote, protamine (Pr) as low as 0.15 μM. Overall, this work demonstrates a promising, facile, and non-invasive method for Hp detection, which can be extended to biomedical and clinical diagnostics.
More Related Videos
Related Concept Videos
Ion-Exchange Chromatography
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Anticoagulant Drugs: Low-Molecular-Weight Heparins