This study aims to establish diagnostic reference levels (DRLs) for common pediatric nuclear medicine (NM) procedures performed within the Dubai Health sector. The established DRLs will serve as a benchmark for pediatric NM practice, supporting standardized healthcare delivery and guiding ongoing quality improvement and internal audit activities. Patient dose survey data were collected from the solo NM center within the Dubai Health sector. The study included common scintigraphy procedures using gamma cameras and the hybrid positron emission tomography with computed tomography (PET/CT) procedures. Scintigraphy procedures include the dynamic and static renal scans, and ocular eye scans. The hybrid PET/CT procedures entail tumor/infection and neuroendocrine scans. Patient demographics, administered activities, CT doses, and study description were recorded. Both weight bands of <5, 5-<15, 15-<30, 30-<50, and 50-<80 kg, and age bands of <1, 1-<5, 5-<10, and 10-<15 years were considered. Statistical analysis was performed to determine the 25th percentile, median and 75th percentile of the dose distribution. The median value was used to establish the DRLs for the Dubai Health sector. The analyses revealed significant variation in the administered activities across the different pediatric NM procedures. The proposed DRLs for various pediatric NM procedures for the weight band 15-<30 kg are as follows: renal dynamic 98.4 MBq, renal static 96.2 MBq, ocular eyes 18.5 MBq, tumor/infection 155 MBq, and neuroendocrine 80 MBq. This work provides the first pediatric NM DRLs for the Dubai Health sector, offering a key reference for developing the local DRLs for the Emirate of Dubai. The findings indicate that achieving meaningful dose optimization will require systematic revision of existing imaging protocols, with targeted parameter adjustments informed by continuous dose monitoring and benchmarking to enhance patient safety and overall diagnostic quality.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Drug Dosing: Infants and Children