Patient-specific fine-tuning of a self-distilled transformer model for normal tissue segmentation in abdominal magnetic resonance guided adaptive radiotherapy
Related Experiment Video
Updated: Aug 14, 2026

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Nicolas Côté1,2, Jue Jiang1, Sharif Elguindi1
1Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Background And Purpose:
Accurate segmentation of organs-at-risk is critical for adaptive Magnetic Resonance guided radiotherapy (MRgRT) in upper gastrointestinal (GI) treatments. Large anatomical variations pose challenges for automated segmentation methods, requiring considerable manual editing. Our goal was to develop and evaluate the effectiveness of patient-specific (PS) fine-tuning of a pretrained transformer model for segmenting upper GI structures.
Materials And Methods:
A PS fine-tuning approach was implemented by adapting a pretrained transformer model called Self-distilled Masked Image Transformer (SMIT). SMIT was trained using T2-weighted MR images from 30 patients with pancreatic cancers who underwent MRgRT to create a general model (GM). This GM was subsequently adapted to each new individual patient using data from their first treatment fraction, producing a PS model. Its performance was evaluated across the subsequent treatment fractions in 10 patients using Dice similarity coefficient (DSC), Hausdorff distance (HD95), and added path length (APL) by comparing against expert delineations.
Results:
PS model outperformed the GM across all structures, with the largest improvements for duodenum-stomach (DSC: 0.84 to 0.90, HD95: 15.9 to 4.9 mm). This approach reduced potential contour editing efforts, decreasing median APL by 4%, 7% and 26% for large bowel, small bowel, and duodenum-stomach.
Conclusion:
PS fine-tuning was most effective for scans with low soft-tissue contrast and challenging anatomy. This method provides a practical, computationally feasible approach to enhance online adaptive workflow by improving segmentation accuracy and potentially reducing the need for manual editing that overall improves on-table treatment times.
More Related Videos
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET