Hemodynamic analysis of the aortic root based on differences in outflow graft angle in patients with implantable left
Hiroaki Yamamoto1, Hiroki Kohno2, Hiroki Ikeuchi2
1Department of Cardiovascular Surgery, Chiba University Hospital, 1-8-1, Inohana, Chuo-ku, Chiba, 260-8677, Japan. ha1cy0nb00k@gmail.com.
Abstract:
Aortic insufficiency (AI) that develops during long-term support with continuous-flow left ventricular assist devices (LVADs) remains a significant clinical problem. Abnormal flow patterns and altered wall shear stress (WSS) on the aortic valve are believed to contribute to leaflet remodeling, yet the hemodynamic influence of outflow graft orientation in patient-specific anatomies is not fully understood. This study investigated how different outflow graft angles affect aortic valve WSS and coronary perfusion using computational fluid dynamics (CFD). Three LVAD recipients who underwent preoperative ECG-gated coronary CT were retrospectively analyzed. Patient-specific geometries of the ascending aorta, aortic root, and coronary arteries were reconstructed. A cylindrical outflow graft was virtually anastomosed 25 mm above the sino-tubular junction, and three inclination angles (30°, 60°, 90°) were modeled with a fixed azimuthal angle of 90°. CFD simulations were performed under constant LVAD inflow (5.0 L/min) and uniform outlet pressure conditions. WSS on the aortic valve cusps and coronary flow rates were evaluated after achieving quasi-steady flow. Increasing outflow graft angle resulted in higher WSS on the ascending aortic wall opposite the anastomosis and consistently elevated WSS on the left coronary cusp. In some cases, the non-coronary cusp also showed localized WSS increases. Coronary flow decreased with shallower graft angles, with left coronary artery flow approximately halved at 30° compared with 90°, while right coronary flow exhibited a smaller reduction. Outflow graft angle substantially affects aortic valve WSS distribution and coronary perfusion. Steeper angles increase leaflet WSS, whereas shallower angles reduce coronary flow. Patient-specific CFD simulations may aid in optimizing graft positioning and reducing the risk of AI progression in LVAD patients.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024