Transient Neonatal Cyanosis Exacerbated by Inhaled Nitric Oxide
Kaquanta Barlow1, Charles J Sadle1, Vidhi Jhaveri1
1Department of Pediatrics, UC Davis Children's Hospital, Sacramento, California, United States.
Background:
Methemoglobinemia in newborns presents with cyanosis and hypoxemia, which can be mistaken for congenital heart disease or pulmonary hypertension.
Case Report:
A term infant presented with cyanosis and low SpO 2 (70s) immediately after birth, despite continuous positive airway pressure (CPAP) and 100% inspired oxygen. The patient was intubated and started on inhaled nitric oxide (iNO) and prostaglandin E1 infusion. Chest X-ray showed bilateral pneumothoraces; the echocardiogram was normal. Arterial blood gases demonstrated normal pH and elevated PaO 2 . iNO and prostaglandin E1 (PGE1) were discontinued. Attempts to obtain methemoglobin levels via a co-oximeter panel were unsuccessful, presumably due to out-of-range values. The infant's father revealed that he also had transient cyanosis as an infant. The infant was treated with ascorbic acid. A blood sample sent to a reference laboratory a day after discontinuation of inhaled NO showed a methemoglobin level of 10.2%. Targeted gamma globin gene sequencing found a heterozygous likely pathogenic variant in hemoglobin subunit gamma 2 (HBG2) (p.His63Tyr). He was discharged home at 1 week of age on room air.
Conclusion:
Hereditary causes of methemoglobinemia should be considered for newborns with persistent cyanosis with low SpO 2 and elevated PaO 2 . Detailed family history and avoiding triggers of methemoglobinemia, such as iNO, are the cornerstones of management.
More Related Videos
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Pulmonary Cycle: Exhalation
Oxygen Transport in the Blood
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...