3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Axial X-Ray Microscopy in Nanotomography
Konstantin P Gaikovich1, Ilya V Malyshev1, Dmitry G Reunov1
1Institute for Physics of Microstructures, Russian Academy of Sciences, 603950 Nizhny Novgorod, Russia.
Background/Objectives:
This article develops theory and methods for 3D tomographic imaging of absorption coefficient distributions using axial scanning with EUV microscopes at 46× and 345× magnification. Unlike conventional CT that requires sample rotation, axial scanning moves cells through the microscope focus. The aim is tomographic reconstruction of living cell fine structure without the organelle staining used in optical fluorescence microscopy or ultra-thin cell slicing as in electron microscopy.
Methods:
By generalizing the geometric-optical approximation for small absorption coefficient inhomogeneities in absorbing media, we derived a new explicit tomography equation and solution algorithm validated through numerical simulation. The approach was applied to Convallaria cell analysis using the ×46 microscope. For the ×345 microscope, we developed an alternative method where the kernel of the tomography integral equation was determined experimentally using gold nanospheres with known absorption coefficient, shape, and position. This method was tested through modeling and applied to diagnostics of Convallaria and mouse cerebellar granule cells.
Results:
The developed methods resolve subcellular features down to 140 nm using the ×46 microscope and 50 nm using the ×345 microscope. Thin low-contrast intracellular structures and individual 50-100 nm organelles were detected.
Conclusions:
Methods for retrieving absorption coefficient distributions in cone-beam geometry based on geometric-optical theory generalization and on calibration by gold nanoparticles have been developed and validated through numerical simulation and cell analysis. These methods demonstrate for the first time the effectiveness of axial nanotomography using multilayer mirror microscopes for cell diagnostics.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Overview of Microscopy Techniques
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Three-Dimensional Microscopy in Microbiology
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...