Related Experiment Videos
The gravity suit: a major advance in management of gynecologic blood loss
Obstetrics and Gynecology
|February 1, 1979
Abstract:
We have used the gravity suit (G-suit) to stabilize patients in shock as a result of ruptured ectopic pregnancies. Four patients presenting in shock were carefully studied with serial vital signs, fluid replacement, and blood loss before and after application of the G-suit. These studies were continued through surgery and the removal of the G-suit. The G-suit improved vital signs, increased peripheral organ and limb perfusion, and decreased blood loss in all cases.