Related Experiment Video
Updated: Mar 29, 2026

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
Derivation-Based Calibration of IMUs Using Savitzky-Golay Filters
Diogo Vieira1,2,3, Miguel Oliveira1,2,3, Rafael Arrais4,5
1Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.
Abstract:
For any robotic application, accurate sensor calibration is crucial. In the case of mobile platforms or flying drones, a sensor commonly utilized is the Inertial Measurement Unit (IMU). Current approaches to the calibration of IMU-equipped robotic systems focus on sensor-to-sensor calibration, meaning a second sensor is necessary for the calibration process. Furthermore, a great number of those rely on integrating the sensor measurements to obtain its pose, which leads to integration errors. In this work, we present a method for the extrinsic calibration of IMUs in robotic systems, which avoids the errors originating from IMU integration by instead taking a derivative approach using Savitzky-Golay filters. The proposed calibration method estimates the transformation between an IMU sensor and its parent frame in the system's kinematic chain by minimizing the differences between derived linear accelerations and angular velocities and those measured by the sensor. Simulated data is used to establish a ground truth against which the calibration results are compared. Results indicate that the proposed method achieves a higher accuracy than the alternatives it is compared against, while also showing the method can be applied to industrial-grade IMUs.
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Application of Linearization and Approximation
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....