Related Experiment Video
Updated: Apr 1, 2026

Dual-Color Fluorescence Cross-Correlation Spectroscopy to Study Protein-Protein Interaction and Protein Dynamics in Live Cells
Published on: December 11, 2021
Time-resolved XPCS analysis across broad time-scales using multi-tau two-time correlations
Fabio Brugnara1, Marco Cammarata2, Yuriy Chushkin2
1Department of Physics, University of Trento, Via Sommarive 14, 38123 Trento, Italy.
Abstract:
We present a multi-tau two-time correlation (MT-2TC) analysis for X-ray photon correlation spectroscopy that enables efficient analysis of large-scale, high-frame-rate datasets collected at modern synchrotron beamlines. The method combines the advantages of the multi-tau autocorrelation and two-time correlation approaches, maintaining sensitivity to non-stationary dynamics while reducing computational complexity and memory requirements from quadratic to linear scaling with the number of frames. This formulation not only improves processing efficiency but also extends the accessible correlation time range, allowing analysis over much broader time scales than conventional techniques. The algorithm is implemented in both dense and sparse data representations, allowing direct processing of sparsified photon-counting data from ultra-fast detectors. We demonstrate the performance of the MT-2TC scheme using experiments on a bulk GeO2 glass and on a v-Ta2O5 thin film conducted at the ESRF ID10 beamline with a 1 kHz Eiger 4M detector. The results show perfect agreement with standard correlation analyses while extending the temporal correlation range by nearly two decades and improving signal-to-noise ratios at long lag times. The MT-2TC approach thus provides a scalable and flexible tool for XPCS at fourth-generation synchrotrons, where enhanced coherent flux and detector speed demand correlation strategies capable of spanning microsecond-to-day timescales.
More Related Videos
06:08Time-resolved Photophysical Characterization of Triplet-harvesting Organic Compounds at an Oxygen-free Environment Using an iCCD Camera
Published on: December 27, 2018
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Related Concept Videos
2D NMR: Overview of Heteronuclear Correlation Techniques
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...