Optimal energy level of virtual monoenergetic images for iron detectability in dual-energy CT: a Phantom study
Lukkana Apipunyasopon1, Petcharleeya Suwanpradit2, Pakjira Saruang3
1Department of Radiological Technology and Medical Physics, Faculty of Allied Health Sciences, Chulalongkorn University, 154 Rama 1 Rd., Pathumwan, Bangkok, 10330, Thailand. l.apipanyasopon@gmail.com.
Abstract:
Different energy levels of virtual monoenergetic images (VMI) characterize the attenuation properties of the image material. This study aims to investigate the optimal energy level of VMI for accurately determining the CT numbers of iron-containing materials in blood at different locations across varying conditions. A phantom containing blood-iron materials with relative electron densities of 1.03, 1.07, and 1.10 was scanned using a dual-energy CT across monoenergetic levels ranging from 40 to 140 keV at the noise indices of 15, 20, and 25. Images were reconstructed using the adaptive statistical iterative reconstruction-V (ASIR-V) technique at different strength levels. The CT numbers and relative percentage error (RPE) were analyzed for rods positioned at inner and outer locations. The RPEs of the CT numbers on VMIs at 80 keV were within ±5% under all examined conditions. At lower and higher VMI energy levels, the RPEs were greater than ±5%. The selection of VMI energy that yields accurate CT numbers should be considered in conjunction with the iron accumulation. The location of rods has a minimal effect on the CT number accuracy. Higher noise indices degraded accurate CT numbers, while higher strength levels of the ASIR-V algorithm suppressed noise, especially at low keV levels. VMI at 80 keV provides the CT number that most accurately reflects the theoretical value throughout all study settings. These findings support the optimization of clinical practices that require precise iron quantification under a low-dose protocol and in a larger patient size.
More Related Videos
05:30Measurement of Tumor T2* Relaxation Times after Iron Oxide Nanoparticle Administration
Published on: May 19, 2023
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...