Related Experiment Video
Updated: Apr 9, 2026

Subjective Refraction Test Using a Smartphone for Vision Screening
Published on: October 18, 2024
The Use of Digital Integrated Manifest Refraction in Pseudophakic Eyes
Pablo A Barragán-Castillo1,2, Felix Piloto-Reyes1, Erik Navas-Villar1,2
1Anterior Segment Service CODET Vision Institute, Tijuana, Mexico.
Purpose:
To evaluate the accuracy and efficiency of a digital integrated manifest refraction system compared with standard manifest refraction in pseudophakic eyes.
Methods:
This prospective, double-blind study analyzed 100 eyes from 100 pseudophakic patients; 35 eyes received monofocal intraocular lenses MA60AC (AcrySof three-piece IOL; Alcon Laboratories, Inc], MX60 (enVista; Bausch & Lomb, Inc), CNA00 (Clareon Monofocal, Alcon Laboratories, Inc), and SN60AT (AcrySof IQ Monofocal; Alcon Laboratories, Inc) and 65 eyes received trifocal IOLs TFNT00 (AcrySof IQ PanOptix; Alcon Laboratories, Inc) and ZFR00V (Synergy; Johnson & Johnson Surgical Vision, Inc). All patients underwent objective refraction with the Nidek ARK-530A autorefractor, followed by manifest refraction performed with the Topcon VT-100 (Std-MR group) and the digital integrated manifest refraction unit TS-610 (Nidek Co, Ltd) (DI-MR group). Outcomes assessed included manifest spherical equivalent, refractive cylinder, time, correlation, and agreement between methods.
Results:
The mean manifest spherical equivalent was -0.15 ± 0.38 diopters (D) with the TS-610 and -0.14 ± 0.38 D with standard refraction (P = .31). Linear regression demonstrated a strong correlation between methods (R = 0.914, R2 = 0.835, P < .001). The mean cylinder was -0.66 ± 0.52 D (TS-610) versus -0.62 ± 0.57 D (Std-MR), with a mean difference of -0.11 ± 0.17 D and a centroid of 0.01 ± 0.20 D in vector analysis. DI-MR significantly reduced testing time (3.1 ± 1.8 minutes) compared with Std-MR (7.1 ± 7.4 minutes, P = .001).
Conclusions:
The automated TS-610 manifest refraction system demonstrated excellent agreement with Std-MR refraction in pseudophakic eyes, while significantly reducing testing time. DI-MR provides a reliable and efficient alternative for postoperative evaluation and may enhance workflow efficiency in cataract and refractive practices.
Related Concept Videos
Focusing of Light in the Eye
Depth Perception and Spatial Vision