Secondary hemodialysis catheter malposition associated with azygos vein dilation in the setting of acute hemodynamic
Masato Obayashi1,2, Toru Iwahashi2, Shun Suzuki2
1Nurse Practitioner Management Office, Department of Clinical Support, Tokyo Medical University Hospital, Tokyo, Japan.
Abstract:
We report a case of secondary hemodialysis catheter migration into the azygos vein in a 53-year-old critically ill woman. Despite correct initial catheter placement under fluoroscopy, the catheter tip migrated into the azygos arch 4 hours later. Retrospective imaging revealed that the azygos arch had dilated from 3.4 mm to 9.2 mm, likely associated with high positive-pressure ventilation and fluid overload. This case suggests that azygos vein dilation during various procedures may contribute to catheter malposition. These findings indicate that, in critically ill patients, initial imaging alone may be insufficient for accurate catheter placement, suggesting the importance of continuous postprocedural monitoring.
More Related Videos
Related Concept Videos
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications
Cardiac Catheterization IV: Nursing Management
Hemodialysis III: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Veins of Thorax
The azygos vein, positioned just right of the midline and anterior to the vertebral column, begins at the junction of the right ascending lumbar and subcostal veins, terminating in the superior vena cava. This vein drains blood from the right side of the thoracic wall, thoracic viscera, and posterior abdominal wall.
The...