One Year Longitudinal Assessment of Subjective and Objective Accommodation After Phakic IOL Implantation
Esther López-Artero1,2, María García-Montero2, Blanca Poyales1
1Miranza Group, C/Galileo 104, 28003 Madrid, Spain.
Purpose:
To evaluate the 1 year behavior of accommodation and optical quality one year after the implantation of phakic intraocular lenses, specifically the implantable collamer lens (ICL), in myopic patients, comparing outcomes between low- and high-myopia groups.
Methods:
This comparative longitudinal study included 38 eyes of 38 patients who underwent ICL implantation for myopia correction. Patients were divided into two groups based on preoperative manifest sphere: low myopia (-2.50 D to -6.25 D) and high myopia (>-6.25 D to -12.50 D). The amplitude of accommodation (AA), subjective accommodative response (AR), optical quality parameters including the modulation transfer function (MTF) cut-off, objective scatter index (OSI) and Strehl ratio (SR), and objective accommodative response with a double-pass system (HD Analyzer, Visiometrics) were assessed preoperatively, 1 month, and 1 year postoperatively.
Results:
Both groups achieved postoperative refractive outcomes close to emmetropia, with high efficacy and safety indices. A statistically significant decrease in the amplitude of accommodation was observed at 1 month and remained stable at 1 year in both groups; however, this change was not clinically meaningful. The optical quality parameters (MTF cut-off, OSI, and Strehl ratio) and objective accommodative response with the HD Analyzer showed no clinically relevant changes over time, with no significant intergroup differences detected (p-value > 0.05).
Conclusions:
An initial reduction in accommodative amplitude was observed after ICL implantation without recovery over time; however, it was not clinically relevant, as it fell within the test-retest variability in the minus lens technique. Other accommodative parameters and optical quality remained stable at 1 year in both low and high myopia.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Related Concept Videos
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...