EHR Sampling Interval Bias Detection and Burden of Blood Pressure Excursions: Implications for Clinical Decision
Neel Shah1, Ethan Sanford2,3, David R Busch3,4,5
1Department of Pediatrics, Washington University in St. Louis, 660 S. Euclid Ave., St. Louis, MO 63130, USA.
Abstract:
Routine Electronic Health Record (EHR) blood pressure charting under-samples dynamic physiology, risking missed hemodynamic instability. This study quantifies how HER-like down-sampling changes the detection and burden of hypo- and hypertension versus continuous monitoring and articulates the consequences for clinical decision support and machine learning label quality. We retrospectively analyzed 78 ECMO-supported pediatric patients (2019-2023). The continuous mean arterial pressure (MAP) captured every 5 s was resampled at intervals from 5 s to 1 h. We screened for 3 min windows of hypotension or hypertension at 10th/90th age-normed thresholds, comparing the per-patient event frequency and burden with EHR-derived recordings. At 10th/90th thresholds, hypotension events fell from 13,936 (5 s) to 3803 (15 min; -72.7%); the EHR captured 3471. Hypertension events dropped from 1573 to 410 (-73.9%); the EHR registered 1587. The EHR data overstated hypertension burden, indicating preferential documentation during prolonged instability while missing brief excursions. Standard EHR sampling significantly under-reports blood pressure derangements in pediatric ECMO. This underreporting of brief events may limit the accuracy of clinical decision support tools and machine learning algorithms in high-acuity patients. High-frequency data acquisition improves event capture and should be prioritized for clinical decision support and machine learning development.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: